NZMS2-M63 109973 EATON ELECTRIC Int. automatische NZM, 3P, Iu: 63 a Vergrößern
Die Bilder sind nur orientativ. Bitte prüfen Sie das Artikelstammdatenblatt.

NZMS2-M63 109973 EATON ELECTRIC Int. automatische NZM, 3P, Iu: 63 a

NZMS2-M63

109973

Y7-109973

EATON-MOELLER

Int. automatische NZM, 3P, Iu: 63 a

NZMS2-M63. Circuit-breaker 3 pole, 63A, motor protection

Mehr Infos


Leistungsschalter NZM

* Neues Produkt in der Originalverpackung mit allen Garantien und Zertifizierungen von EATON-MOELLER

Gesamtpreis: $495.90
Stückpreis: $495.90

*Dieser Preis ist pro Einheit und ist der Nettowert (ohne Steuern, falls zutreffend).

Wenn unser Preis nicht der beste ist, fragen Sie uns nach einem Angebot Fordern Sie ein Angebot

ANGESEHENE ARTIKEL


Bestseller

Mehr Infos



Allgemeine Spezifikation

Product Name
Eaton Moeller series NZM molded case circuit breaker thermo-magnetic
Catalog Number
109973
Product Length/Depth
149 mm
Product Height
184 mm
Product Width
105 mm
Product Weight
2.358 kg
Compliances
RoHS conform
EAN
4015081095391
Model Code
NZMS2-M63

Produktspezifikationen

Special features
Rated current = rated uninterrupted current: 63 ATripping class 10 AIEC/EN 60947-4-1, IEC/EN 60947-2The circuit-breaker fulfills all requirements for AC-3 switching category.
Amperage Rating
63 A
Voltage rating
690 V - 690 V
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Mounting Method
Built-in device fixed built-in technique
Equipment heat dissipation, current-dependent
20.24 W
Ambient operating temperature - max
70 °C
Ambient operating temperature - min
-25 °C
Ambient storage temperature - max
70 °C
Ambient storage temperature - min
40 °C
Rated operating power at AC-3, 230 V
18.5 kW
Rated operating power at AC-3, 400 V
30 kW
Switch off technique
Thermomagnetic
Degree of protection
IP20
Electrical connection type of main circuit
Screw connection
Rated operational current
55 A (400 V AC-3)
Number of poles
Three-pole
Functions
Phase failure sensitive
Short-circuit release non-delayed setting - max
882 A
Short-circuit release non-delayed setting - min
504 A
Handle type
Rocker lever
Instantaneous current setting (Ii) - max
882 A
Instantaneous current setting (Ii) - min
504 A
Overload current setting (Ir) - max
63 A
Overload current setting (Ir) - min
50 A
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz
150 kA
Rated short-circuit breaking capacity Icu (IEC/EN 60947) at 400/415 V, 50/60 Hz
150 kA

Datasheet - PDF

Bewertungen (0)

Es gibt keine Produktbewertungenvor.

Bewertung abgeben
Formular verstecken
Wertung:
Name:
E-Mail :
Betreff:
Text:
  Captcha
  Bewertung abgeben

Alle Bewertungen wir von den Einzelteilen erhalten wir anbieten, sind real und verifiziert. Eine kleine Geste, aber sehr wertvoll. Also danke für die Minute, die Sie in, dass Sie uns Ihre Meinung und Bewertung von Produkten ausgeben, weil es mir hilft, weiter zu verbessern und noch mehr Servicequalität zu bieten.