3RA2210-0FS15-2BB4
SIEMENS
1
Load feeder fuseless, Reversing duty 400 V AC, Size S00 0.35...0.50 A 24 V DC Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor) Adapter length 200 mm
SIRIUS Innovations Bypass Motor Inverter Starter, 400V AC, size S00 0.35...0.50A 3kW, 24V DC spring connection 1NA for 60mm busbars (also meets coord. type 1) coord type. 2, Icc / Iq = 150kA 1NA (contactor) adapter length 200mm. Manufactured to order. Non-Cancelable Non-Returnable.
Low-voltage industrial components > Motor starter/Motor starter combination
CONTROL AND CONTACTORS > Contactors for switching motors
* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product | |||||||||||||||||||||||||||||||||||||
Article Number (Market Facing Number) | 3RA2210-0FS15-2BB4 | ||||||||||||||||||||||||||||||||||||
Product Description | Load feeder fuseless, Reversing duty 400 V AC, Size S00 0.35...0.50 A 24 V DC Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor) Adapter length 200 mm | ||||||||||||||||||||||||||||||||||||
Product family | SIRIUS 3RA2 load feeders | ||||||||||||||||||||||||||||||||||||
Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
Price data | |||||||||||||||||||||||||||||||||||||
Region Specific PriceGroup / Headquarter Price Group | 41D / 41D | ||||||||||||||||||||||||||||||||||||
Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
Metal Factor | LCO----- | ||||||||||||||||||||||||||||||||||||
Delivery information | |||||||||||||||||||||||||||||||||||||
Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
Standard lead time ex-works | On request | ||||||||||||||||||||||||||||||||||||
Net Weight (kg) | 1,863 Kg | ||||||||||||||||||||||||||||||||||||
Packaging Dimension | 246,00 x 326,00 x 222,00 | ||||||||||||||||||||||||||||||||||||
Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
Additional Product Information | |||||||||||||||||||||||||||||||||||||
EAN | 4011209937499 | ||||||||||||||||||||||||||||||||||||
UPC | Not available | ||||||||||||||||||||||||||||||||||||
Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
Product Group | 5348 | ||||||||||||||||||||||||||||||||||||
Group Code | R711 | ||||||||||||||||||||||||||||||||||||
Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 | ||||||||||||||||||||||||||||||||||||
Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
Classifications | |||||||||||||||||||||||||||||||||||||
|
Value | Unit | |
---|---|---|
Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
Ambient temperature, upper operating limit (EF009603) | - | °C |
External reset possible (EF003426) | - | |
Supporting protocol for Modbus (EF003057) | - | |
Supporting protocol for DeviceNet (EF003059) | - | |
Supporting protocol for Data-Highway (EF003058) | - | |
Suitable for emergency stop (EF001433) | - | |
Supporting protocol for SafetyBUS p (EF007527) | - | |
Supporting protocol for PROFINET IO (EF007525) | - | |
Supporting protocol for PROFINET CBA (EF007524) | - | |
Rail mounting possible (EF003972) | - | |
Supporting protocol for other bus systems (EF003062) | - | |
Supporting protocol for CAN (EF003053) | - | |
Degree of protection (NEMA) (EF011959) | - | |
Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
Supporting protocol for PROFIBUS (EF003052) | - | |
Supporting protocol for LON (EF003017) | - | |
Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
Supporting protocol for PROFIsafe (EF007526) | - | |
Supporting protocol for Foundation Fieldbus (EF007522) | - | |
Supporting protocol for DeviceNet Safety (EF007520) | - | |
Supporting protocol for SUCONET (EF003060) | - | |
Supporting protocol for TCP/IP (EF003050) | - | |
Supporting protocol for ASI (EF003051) | - | |
Supporting protocol for INTERBUS (EF003054) | - | |
Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
Temperature compensated overload protection (EF009604) | - | |
Number of command positions (EF001372) | - | |
Supporting protocol for SERCOS (EF006657) | - | |
Supporting protocol for INTERBUS-Safety (EF006662) | - | |
Supporting protocol for EtherNet/IP (EF007521) | - | |
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
Type of motor starter (EF009598) | Other | |
With short-circuit release (EF006691) | true | |
Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
Voltage type for actuating (EF008242) | DC / DC | |
Rated operation power at AC-3, 400 V (EF001364) | 0.12 | kW |
Rated operation current Ie (EF001443) | 0.44 | A |
Rated operation current at AC-3, 400 V (EF009602) | 0.44 | A |
Overload release current setting (EF002336) | ['0.35', '0.5'] | A |
Number of auxiliary contacts as normally open contact (EF001376) | - | |
Number of auxiliary contacts as normally closed contact (EF001377) | - | |
Release class (EF006668) | CLASS 10 | |
Type of electrical connection of main circuit (EF006819) | Spring clamp connection | |
With transformer (EF000278) | false | |
Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
Number of indicator lights (EF001965) | 0 | |
With fuse (EF006693) | false | |
Degree of protection (IP) (EF005474) | IP20 | |
Width (EF000008) | 90.0 | mm |
Height (EF000040) | 212.0 | mm |
Depth (EF000049) | 155.0 | mm |
Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes |
![]() |
3RA2210-0FS15-2BB4 3RA2210-0FS15-2BB4 EN_3RA2210-0FS15-2BB4.pdf | 323 Kbytes |
![]() |
No customer reviews for the moment.
Rating: |
![]() ![]() ![]() ![]() ![]() |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
|
|
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.