3TC4817-0BD0 SIEMENS Contactor size 4, 2-pole DC-3 and 5, 75 A Auxiliary switch 22 (2 NO + 2 NC) Alternating.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3TC4817-0BD0 SIEMENS Contactor size 4, 2-pole DC-3 and 5, 75 A Auxiliary switch 22 (2 NO + 2 NC) Alternating..

3TC4817-0BD0

SIEMENS

Contactor size 4, 2-pole DC-3 and 5, 75 A Auxiliary switch 22 (2 NO + 2 NC) Alternating current operation 42 V AC 50 Hz/50 V AC 60 Hz

More details


Low-voltage industrial components > Power contactor, DC switching

CONTROL AND CONTACTORS > Contactors for switching motors

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $739.47
Unit price: $739.47

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC002552 - Power contactor, DC switching

Value Unit
Rated control supply voltage Us at AC 50HZ (EF003978) ['42.0', '42.0']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['50.0', '50.0']V
Rated control supply voltage Us at DC (EF003980) ['-', '-']V
Voltage type for actuating (EF008242) AC
Rated operation power at DC-3 / DC-5 at 440 V (EF007026) 27.0kW
Rated operation current Ie at DC-3 / DC-5 at 440 V (EF007035) 75A
Modular version (EF001126) true
Number of auxiliary contacts as normally open contact (EF001376) 2
Number of auxiliary contacts as normally closed contact (EF001377) 2
Type of electrical connection of main circuit (EF006819) Screw connection
Number of normally closed contacts as main contact (EF001375) 0
Number of main contacts as normally open contact (EF001374) 2


Contactor size 4, 2-pole DC-3 and 5, 75 A Auxiliary switch 22 (2 NO + 2 NC) Alternating current operation 42 V AC 50 Hz/50 V AC 60 Hz
Product designationContactor
Product type designation3TC
General technical data
Size of contactor4
Product extension
● function module for communicationNo
● Auxiliary switchYes
Insulation voltage rated value800 V
maximum permissible voltage for safe isolation between coil and main contacts acc. to EN 60947-1300 V
● Protection class IPIP00
● protection class IP on the frontIP00
● Protection class IP of the terminalIP00
Shock resistance at rectangular impulse
● at AC10g / 5 ms, 5g / 10 ms
Mechanical service life (switching cycles)
● of contactor typical10 000 000
● of the contactor with added auxiliary switch block typical10 000 000
Reference code acc. to DIN EN 81346-2Q
Ambient conditions
Ambient temperature
● during operation-25 ... +55 °C
● during storage-50 ... +80 °C
Main circuit
number of poles2
Number of poles for main current circuit2
Number of NO contacts for main contacts2
Number of NC contacts for main contacts0
type of voltageDC
Operating current
● with 2 current paths in series at DC-1
— at 24 V rated value75 A
— at 110 V rated value75 A
— at 220 V rated value75 A
— at 440 V rated value75 A
— at 600 V rated value75 A
Operating current
● at DC-3 at DC-5
— at 220 V rated value75 A
— at 440 V rated value75 A
— at 600 V rated value75 A
— at 750 V rated value75 A
● with 2 current paths in series at DC-3 at DC-5
— at 24 V rated value75 A
— at 110 V rated value75 A
— at 220 V rated value75 A
— at 440 V rated value75 A
— at 600 V rated value75 A
Operating power
● at DC-1
— at 110 V rated value8.2 kW
— at 220 V rated value16.5 kW
— at 440 V rated value33 kW
— at 750 V rated value56 kW
● at DC-3 at DC-5
— at 110 V rated value6.5 kW
— at 220 V rated value13 kW
— at 440 V rated value27 kW
— at 600 V rated value38 kW
— at 750 V rated value45 kW
Operating frequency
● at DC-1 maximum1 000 1/h
● at DC-3 maximum600 1/h
● at DC-5 maximum600 1/h
Control circuit/ Control
Type of voltage of the control supply voltageAC
Control supply voltage at AC
● at 50 Hz rated value42 V
● at 60 Hz rated value50 V
Operating range factor control supply voltage rated value of magnet coil at AC
● at 50 Hz0.8 ... 1.1
Apparent pick-up power of magnet coil at AC300 V·A
● at 50 Hz300 V·A
● at 60 Hz365 V·A
Inductive power factor with closing power of the coil0.5
● at 50 Hz0.5
● at 60 Hz0.45
Apparent holding power of magnet coil at AC26 V·A
● at 50 Hz26 V·A
● at 60 Hz35 V·A
Inductive power factor with the holding power of the coil0.24
● at 50 Hz0.24
● at 60 Hz0.26
Arcing time20 ... 30 ms
Auxiliary circuit
Number of NC contacts for auxiliary contacts2
● instantaneous contact2
Number of NO contacts for auxiliary contacts2
● instantaneous contact2
Number of CO contacts
● for auxiliary contacts0
Identification number and letter for switching elements22
Operating current at AC-12 maximum10 A
Operating current at AC-15
● at 230 V rated value5.6 A
● at 400 V rated value3.6 A
● at 500 V rated value2.5 A
Operating current at DC-12
● at 24 V rated value10 A
● at 48 V rated value10 A
● at 60 V rated value10 A
● at 110 V rated value3.2 A
● at 125 V rated value2.5 A
● at 220 V rated value0.9 A
● at 600 V rated value0.22 A
Operating current at DC-13
● at 24 V rated value10 A
● at 48 V rated value5 A
● at 60 V rated value5 A
● at 110 V rated value1.14 A
● at 125 V rated value0.98 A
● at 220 V rated value0.48 A
● at 600 V rated value0.07 A
contact reliability of auxiliary contactsone incorrect switching operation of 100 million switching operations (17 V, 5 mA)
UL/CSA ratings
Contact rating of auxiliary contacts according to ULA600 / P600
Short-circuit protection
Design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 requiredgG: 160 A (690 V, 100 kA)
— with type of assignment 2 requiredgG: 63 A (690 V,100 kA)
● for short-circuit protection of the auxiliary switch requiredgG: 16 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-22,5° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface; standing, on horizontal mounting surface
Mounting typescrew fixing
● Side-by-side mountingYes
Height177.5 mm
Width100 mm
Depth156 mm
Required spacing
● with side-by-side mounting
— forwards20 mm
— Backwards0 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
● for grounded parts
— forwards55 mm
— Backwards0 mm
— upwards10 mm
— at the side10 mm
— downwards10 mm
● for live parts
— forwards55 mm
— Backwards0 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
Connections/ Terminals
● type of electrical connectionscrew-type terminals
● Type of electrical connection for main current circuitscrew-type terminals
● Type of electrical connection for auxiliary and control current circuitscrew-type terminals
Type of connectable conductor cross-sections
● for auxiliary contacts
— single or multi-stranded2x (1 ... 2,5 mm²)
— finely stranded with core end processing2x (0.75 ... 2.5 mm²)
Safety related data
Protection against electrical shockfinger-safe only with terminal cover
Certificates/ approvals
General Product ApprovalFunctional Safety/Safety of MachineryDeclaration of Conformity

CCC

CSA

UR

EAC

Type Examination Certificate

EC/EU-Declaration of Conformity

Declaration of ConformityTest CertificatesMarine / Shippingother

Miscellaneous

Special Test Certificate

Miscellaneous

Type Test Certificates/Test Report

RMRS / Russian Maritime Register

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified:08/13/2020


Product
Article Number (Market Facing Number)3TC4817-0BD0
Product DescriptionContactor size 4, 2-pole DC-3 and 5, 75 A Auxiliary switch 22 (2 NO + 2 NC) Alternating current operation 42 V AC 50 Hz/50 V AC 60 Hz
Product familyNot available
Product Lifecycle (PLM)PM300:Active Product
Price data
Price Group41B
Surcharge for Raw MaterialsNone
Metal FactorLDO-----
Delivery information
Export Control RegulationsECCN : N / AL : N
Standard lead time ex-worksOn request
Net Weight (kg)3,380 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension329,00 x 329,00 x 210,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209150812
UPCNot available
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5807
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.03.2017
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
Not available

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.