3RA1130-4FB35-0AB0 SIEMENS Load feeder fuseless direct-on-line starting, 400 V AC 28...40 A, 24 V AC 50 Hz S.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RA1130-4FB35-0AB0 SIEMENS Load feeder fuseless direct-on-line starting, 400 V AC 28...40 A, 24 V AC 50 Hz S..

3RA1130-4FB35-0AB0

SIEMENS

Load feeder fuseless direct-on-line starting, 400 V AC 28...40 A, 24 V AC 50 Hz Size S2 Screw terminal on adapter Screw and snap-on mounting Type of coordination 2, Iq = 50 kA (also fulfills type of coordination 1) !!! Phased-out product !!! Successor is SIRIUS 3RA2

More details


Low-voltage industrial components > Motor starter/Motor starter combination

CONTROL AND CONTACTORS > Contactors for switching motors

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC001037 - Motor starter/Motor starter combination

Value Unit
Supporting protocol for SUCONET (EF003060) -
Supporting protocol for SERCOS (EF006657) -
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) -A
Type of electrical connection for auxiliary- and control current circuit (EF006979) -
Supporting protocol for AS-Interface Safety at Work (EF007519) -
Degree of protection (NEMA) (EF011959) -
Rated conditional short-circuit current, type 2, 230 V (EF009606) -A
Supporting protocol for SafetyBUS p (EF007527) -
Supporting protocol for EtherNet/IP (EF007521) -
Supporting protocol for other bus systems (EF003062) -
Supporting protocol for DeviceNet (EF003059) -
Supporting protocol for Data-Highway (EF003058) -
Supporting protocol for INTERBUS (EF003054) -
Ambient temperature, upper operating limit (EF009603) -°C
Supporting protocol for PROFIsafe (EF007526) -
Supporting protocol for Foundation Fieldbus (EF007522) -
Supporting protocol for PROFIBUS (EF003052) -
Supporting protocol for TCP/IP (EF003050) -
Suitable for emergency stop (EF001433) -
Supporting protocol for Modbus (EF003057) -
Rated operation power at AC-3, 230 V, 3-phase (EF009599) -kW
Rated conditional short-circuit current, type 2, 400 V (EF009605) -A
Rated power, 460 V, 60 Hz, 3-phase (EF009600) -kW
Supporting protocol for PROFINET CBA (EF007524) -
Supporting protocol for DeviceNet Safety (EF007520) -
Release class (EF006668) -
Supporting protocol for INTERBUS-Safety (EF006662) -
Supporting protocol for PROFINET IO (EF007525) -
Rated power, 575 V, 60 Hz, 3-phase (EF009601) -kW
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) -A
Temperature compensated overload protection (EF009604) -
Number of command positions (EF001372) -
Supporting protocol for LON (EF003017) -
Supporting protocol for CAN (EF003053) -
External reset possible (EF003426) -
Rail mounting possible (EF003972) -
Type of motor starter (EF009598) Direct online starter (DOL)
With short-circuit release (EF006691) true
Rated control supply voltage Us at DC (EF003980) ['-', '-']V
Voltage type for actuating (EF008242) AC / #NO_DATA#
Rated operation power at AC-3, 400 V (EF001364) 18.5kW
Rated operation current Ie (EF001443) 35A
Rated operation current at AC-3, 400 V (EF009602) 35A
Overload release current setting (EF002336) ['28', '40']A
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as normally closed contact (EF001377) 0
Type of electrical connection of main circuit (EF006819) Screw connection
With transformer (EF000278) false
Coordination class according to IEC 60947-4-3 (EF012390) Class 2
Number of indicator lights (EF001965) 0
With fuse (EF006693) false
Degree of protection (IP) (EF005474) IP20
Supporting protocol for ASI (EF003051) false
Width (EF000008) 55.0mm
Height (EF000040) 295.0mm
Depth (EF000049) 173.0mm
Rated control supply voltage Us at AC 50HZ (EF003978) -V
Rated control supply voltage Us at AC 60HZ (EF003979) -V


Load feeder fuseless direct-on-line starting, 400 V AC 28...40 A, 24 V AC 50 Hz Size S2 Screw terminal on adapter Screw and snap-on mounting Type of coordination 2, Iq = 50 kA (also fulfills type of coordination 1) !!! Phased-out product !!! Successor is SIRIUS 3RA2
product brand nameSIRIUS
Product designationnon-fused load feeder
Design of the productdirect starter
Manufacturer's article number
● of the supplied contactor3RT1035-1AB00
● of the supplied circuit-breakers3RV1031-4FA10
● of the supplied link module3RA1931-1AA00
● of the supplied standard mounting rail adapter3RA1932-1AA00
General technical data
Size of load feederS2
Product extension
● Auxiliary switchYes
● Insulation voltage rated value690 V
Degree of pollution3
Surge voltage resistance rated value6 kV
● protection class IP on the frontIP20
Shock resistance8g
Mechanical service life (switching cycles)
● of contactor typical10 000 000
Type of assignment2
● certificate of suitabilityUL / CSA / CCC / GL / LRS / BV / DNV / PRS
Reference code acc. to DIN EN 81346-2Q
Ambient conditions
Installation altitude at height above sea level
● maximum2 000 m
Ambient temperature
● during operation-20 ... +70 °C
● during storage-55 ... +80 °C
Main circuit
Number of poles for main current circuit3
design of the switching contactelectromechanical
adjustable pick-up value current of the current-dependent overload release28 ... 40 A
Type of the motor protectionbimetal
Operating voltage
● at AC-3 rated value maximum400 V
Operating current
● at AC-3
— at 400 V rated value35 A
Operating power
● at AC-3
— at 400 V rated value18.5 kW
No-load switching frequency15 1/s
Control circuit/ Control
Type of voltage of the control supply voltageAC
Control supply voltage 1 at AC
● at 50 Hz rated value24 V
control supply voltage frequency
● 1 rated value50 Hz
Auxiliary circuit
Number of NC contacts for auxiliary contacts0
Number of NO contacts for auxiliary contacts0
Number of CO contacts
● for auxiliary contacts0
Protective and monitoring functions
Maximum short-circuit current breaking capacity (Icu)
● at 400 V rated value50 kA
Short-circuit protection
product function short circuit protectionYes
Design of short-circuit protectioncircuit-breakers
Installation/ mounting/ dimensions
● mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Mounting typesnap-on fastening on 35 mm standard rail
Height295 mm
Width55 mm
Depth173 mm
Required spacing
● with side-by-side mounting
— at the side0 mm
● for grounded parts
— forwards10 mm
— Backwards0 mm
— upwards50 mm
— at the side10 mm
● for live parts
— forwards10 mm
— Backwards10 mm
— downwards0 mm
— at the side50 mm
Connections/ Terminals
● Type of electrical connection for main current circuitscrew-type terminals
Type of connectable conductor cross-sections
● for main contacts
— solid0.7 ... 35 mm², 2x (0.75 ... 25 mm²)
— stranded0.7 ... 35 mm², 2x (0.75 ... 25 mm²)
— finely stranded with core end processing0.75 ... 25 mm², 2x (0.75 ... 16 mm²)
● at AWG conductors for main contacts2x (30 ... 2)
Connectable conductor cross-section for main contacts
● single or multi-stranded0.7 ... 35 mm²
● stranded0.7 ... 35 mm²
● finely stranded with core end processing0.75 ... 25 mm²
AWG number as coded connectable conductor cross section
● for main contacts30 ... 2
Communication/ Protocol
● protocol is supported PROFIBUS DP protocolNo
● protocol is supported PROFINET protocolNo
product function bus communicationNo
Protocol is supported
● AS-Interface protocolNo
Inputs/ Outputs
● number of digital inputs0
Certificates/ approvals
General Product ApprovalFor use in hazardous locationsDeclaration of ConformityMarine / Shipping

UL

EAC

ATEX-EC-Type-Examination-Certificate

EC/EU-Declaration of Conformity

Miscellaneous

BV / Bureau Veritas

Marine / Shippingother

LR (Lloyds Register)

RMRS / Russian Maritime Register

DNV-GL

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified:08/13/2020


Product
Article Number (Market Facing Number)3RA1130-4FB35-0AB0
Product DescriptionLoad feeder fuseless direct-on-line starting, 400 V AC 28...40 A, 24 V AC 50 Hz Size S2 Screw terminal on adapter Screw and snap-on mounting Type of coordination 2, Iq = 50 kA (also fulfills type of coordination 1) !!! Phased-out product !!! Successor is SIRIUS 3RA2
Product familyNot available
Product Lifecycle (PLM)PM490:Start of final year of support
PLM Effective DateProduct discontinued since: 01.04.2020
Notes
Product is no longer available
Sucessor:SIRIUS Innovation 3RA2
If you need assistance please contact our local Siemens office
Price data
Price Group41D
Surcharge for Raw MaterialsNone
Metal FactorLCO-----
Delivery information
Export Control RegulationsECCN : N / AL : N
Standard lead time ex-works20 Day/Days
Net Weight (kg)2,117 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension65,00 x 302,00 x 192,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209522169
UPCNot available
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group3709
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.07.2006
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
Not available

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.